Using the i/o receptacle, Wiring diagram 1 for sensor input, Wiring diagram 2 for sensor input – Sony IPELA NSR-100 User Manual

Page 171

Advertising
background image

171

Miscellaneous

Using the I/O Receptacle

Insert a small slotted screwdriver into the upper or lower slot of the hole you
want to connect a wire to (AWG No. 28 to 18). Hold down the screwdriver and
insert the wire, then release the screwdriver.

Caution

Do not use excessive force when inserting the screwdriver into the slot. Doing
so may result in damage.

Repeat this procedure to connect all required wires.

Wiring Diagram 1 for Sensor Input

Wiring Diagram 2 for Sensor Input

Note

When the wiring diagram 2 is used, the NSR is not electrically isolated, so be
sure to construct external circuits that will not produce noise, excess voltage, or
overcurrents.

1

2

3

Inside of this unit

Outside

3, 5, 7, 9, 11, 13, 15, 17 pin
(SENSOR IN+)

2, 4, 6, 8, 10, 12, 14, 16 pin
(SENSOR IN-)

2.35 k

Ω

Sensor
device
Output:
3.3 to 24 V
DC

Inside of this unit

Outside

1 pin (VDD) (200 mA max)

Wire

Mechanical switch

or

Open collector output
device

GND

3, 5, 7, 9, 11, 13, 15,
17 pin
(SENSOR IN+)

2, 4, 6, 8, 10, 12, 14,
16 pin
(SENSOR IN-)

18pin (GND)

2.35 k

Ω

Advertising
This manual is related to the following products: