ALARM RECORDING

Alarm Recording Reset Function

To stop the recording of an alarm, close the connection
between the ALARM RESET IN terminal and the COM
terminal during alarm recording.

Alarm Recording Counter Display

œ

During alarm recording, “A” will be flashing on the
digital display.

œ

If a superimpose display is being displayed and
“ALARM COUNT” has been set to “Y” in the
(DISPLAY/SW OUT SET) menu, the number of alarm
recordings will flash on the monitor screen.

œ

The maximum display number of alarm recordings is
“999”. At the next alarm recording the counter will
indicate “000”.

œ

When the (ALARM LOG) menu appears, press the
MENU RESET button to reset the alarm counter to
“000” (all the data of the (ALARM LOG) menu is reset).

Connections to the ALARM IN Terminal

œ

Alarm input signal
Connect a make-contact (no voltage) switch between
the ALARM IN and COM terminals.

Checking the Alarm Recordings Time

1

Press the MENU button to display the MAIN MENU.

2

Turn the JOG dial to select the “9.OTHERS” line,
then turn the SHUTTLE ring clockwise.

ø

The (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1

3

Turn the JOG dial to select the “ALARM LOG” line,
then turn the SHUTTLE ring clockwise.

ø

The (ALARM LOG) menu appears.

ø

The number of alarm recordings, and the 10
most recent alarm recording times are
displayed.

<ALARM@LOG>@@@@@@@@@010

@@@001@@@12-25@19:00

@@@002@@@11-25@23:00

@@@003@@@10-25@15:00

@@@004@@@10-25@08:00

@@@005@@@10-25@06:00

@@@006@@@10-22@19:00

@@@007@@@10-22@17:15

@@@008@@@10-22@15:45

@@@009@@@10-20@10:00

@@@010@@@10-18@12:00

œ

Continue turning the JOG dial to display the next
(or previous) 10 alarm recording entries. When
the number of alarm recording entries reaches
100, the older ones are erased as new ones are
memorized.

4

Press the MENU EXIT button.

NOTE:

œ

If the MENU RESET button is pressed while the
(ALARM LOG) menu is displayed, the displayed data
is erased. “AL” will be erased from the digital display.