Sharp SRT-8040 User Manual

Page 44

Advertising
background image

SETTING FOR RS-485 OR RS-232C USE

The RS-485 interface can be used to operate the VCR
using a SANYO brand system controller. Furthermore,
the RS-232C interface can be used to operate the VCR
using a computer.

NOTES:

œ

This can only be used when the RS-485/232C
interface board (VZU-485/232C) is installed.

œ

Refer to the instruction manuals for the
VZU-485/232C, the system controller and/or the
computer.

Setting the Address and Data Transfer
Speed

œ

Make this setting without a cassette tape inserted.

1

Press the COUNTER RESET button for 3 seconds
or more.

ø

“485” or “232” appears on the digital display.

2

Turn the JOG dial to select the interface being used,
RS-232C or RS-485.

ø

“232” or “485” appears on the digital display.

œ

When setting “232”, carry out step

3

and then

step

6

.

3

Turn the SHUTTLE ring clockwise.

4

Turn the JOG dial to set the VCR address (from 000
to 127).

ø

The address set appears on the digital display.

5

Turn the SHUTTLE ring clockwise.

6

Turn the JOG dial to set the data transfer speed
(19200, 2400, 4800, 9600).

ø

The data transfer speed set appears on the
digital display.

7

When finished, Press the COUNTER RESET button.

NOTE:

œ

When the MENU RESET button is pressed, the
setting appearing on the digital display is reset to the
default setting.

Settings when using RS-485

1

Press the MENU button to display the MAIN MENU.

2

Turn the JOG dial to select the “9.OTHERS” line,
then turn the SHUTTLE ring clockwise.

ø

The (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1

*RS-485@SET

@@STATUS@INFO.@@@Y

@@ALARM@INFO.@@@@Y

3

Turn the JOG dial until the “STATUS INFO.” setting
is highlighted, then turn the SHUTTLE ring clockwise.

4

Turn the JOG dial to set the “STATUS INFO.”
setting, then turn the SHUTTLE ring clockwise.

Y. . . . . . . . . . The VCR status information is

output at the RS-485 connector.

N . . . . . . . . . The status information is not

output at the RS-485 connector.

5

Turn the JOG dial until the “ALARM INFO.” setting is
highlighted, then turn the SHUTTLE ring clockwise.

6

Turn the JOG dial to set the “ALARM INFO.” setting,
then turn the SHUTTLE ring clockwise.

Y. . . . . . . . . . The VCR alarm information (alarm

recording start and stop) and
video loss information are output
at the RS-485 connector.

N . . . . . . . . . The VCR alarm information (alarm

recording start and stop) and
video loss information are not
output at the RS-485 connector.

7

Press the MENU EXIT button.

8

Set the TERMINATE switch on the back panel to the
“ON” or “OFF” position

OFF side . . . Not terminated

ON side . . . . Terminated

NOTE:

œ

When a warning state (non-recording, mechanical
problem or clog detection) occurs, the warning state is
output from the RS-485 connector. However,
non-recording warning states are not output if “NON
REC” is set to “N” in the (WARNING OUT/CONTROL
SET) menu. In addition, the clog detection warning
state is not output if “CLOG DETECT.” is set to “N” in
the (GENERAL SET) menu.

RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002