CLOCK ADJUSTMENT

The time for the second and subsequent VCRs can be
set to the same time as the first VCR.

A signal from a separate device can also be used to set
the time for the second and subsequent VCRs to the
same time as the first VCR. When using the signal from
a separate device to set the time, input a 0 V signal to
the CONTROL IN terminal of the first VCR for 100 ms or
longer.

1

Press the MENU button to display the MAIN MENU.

2

Turn the JOG dial to select the “3.GENERAL SET”
line, then turn the SHUTTLE ring clockwise.

3

Turn the JOG dial until the “CLOCK ADJUST”
setting is highlighted, then turn the SHUTTLE ring
clockwise.

4

Turn the JOG dial to set the hour at which the
adjustment will be conducted, then turn the
SHUTTLE ring clockwise.

NOTE:

œ

The clock adjustment cannot be set to “00:00”.

Example

<GENERAL@SET>

TAPE@IN@MODE@@@@@STOP

TAPE@END@MODE@@@@REW

CLOCK@ADJUST@@@@@03:00

THREAD@CHECK@@@@@N

VIDEO@LOSS@@@@@@@N

CLOG@DETECT.@@@@@N

REMOTE@@@@@@@@@@@MENU

VIDEO@@@@@@@@@@@@COLOR

VERTICAL@SYNC@@@@Y

TAPE@@@@@@@@@@@@@T-160

5

Press the MENU EXIT button.

The setting procedure on the first VCR is now
completed.

6

Repeat the procedure for all the other VCRs, setting
“CLOCK ADJUST” (to the same time as set on the
first VCR).

NOTE:

œ

This function will not operate on the day the daylight
saving/standard time is changed.

Connection

SELECTING INPUT AND OUTPUT TERMINALS

The input and output terminal signals can be selected so
that the VCR can be connected to older models of VCR.

1

Press the MENU button to display the MAIN MENU.

2

Turn the JOG dial to select the “9. OTHERS” line,
then turn the SHUTTLE ring clockwise.

ø

The (OTHERS) menu appears.

<OTHERS>

*ALARM@LOG

*POWER@FAILURE/DEW

*TERMINAL@SET@@@@SET1

3

Turn the JOG dial until the “TERMINAL SET” setting
is highlighted, then turn the SHUTTLE ring clockwise.

4

Turn the JOG dial to select the desired mode, then
turn the SHUTTLE ring clockwise.

SET1 . . . . . . . . . . . . . . According to indication on

back panel. (Select when
not connecting to an older
model.)

SET2 . . . . . . . . . . . . . . CONTROL IN is set to

CLOCK IN, SERIES IN is
set to EJECT IN,
CONTROL OUT is set to
CLOCK OUT and TIMER
OUT
is set to EJECT
OUT
. (Select when
connecting to an older
model.)

5

When finished, press the MENU EXIT button.

NOTE:

œ

If set to “SET2”, the “SERIES REC” line will not
appear in the (ALARM/SERIES REC SET) menu.

VCR No. 1

VCR No. 2

To CONTROL IN terminal

To COM terminal

CONTROL IN

COM

CONTROL OUT

CONTROL IN

COM

CONTROL OUT