6-3 Extended Menu

Menu items in the 400s, relating to preroll

Item number Item name

Settings

401

FUNCTION MODE AFTER CUE-UP Select the state that the unit goes into after a cuing-up operation.

stop: Stops (the STOP mode).
still: Still playback (in search mode).

Menu items in the 600s, relating to the time code and metadata

Item number Item name

Settings

601

VITC POSITION SEL-1

Select a line to insert the VITC in.
12H ... 16H ... 20H (in 525(U)/525(J)-line modes): Select any line from

12 to 20.

9H ... 19H ... 22H (in 625-line mode): Select any line from 9 to 22.

Note

You can insert the VITC signal in two places. To insert it in two places, set
both items 601 and 602.

602

VITC POSITION SEL-2

Select a line to insert the VITC in.
12H ... 18H ... 20H (in 525(U)/525(J)-line modes): Select any line from

12 to 20.

9H ... 21H ... 22H (in 625-line mode): Select any line from 9 to 22.

Note

You can insert the VITC signal in two places. To insert it in two places, set
both items 601 and 602.

605

TCG REGEN MODE

Select the signal to be regenerated when the time code generator is in
the regeneration mode (i.e., when “int regen,” “ext regen” or “rp 188
regen” is selected in menu item 626).
TC&UB: Both the time code and user bits are regenerated.
TC: Only the time code is regenerated.
UB: Only the user bits are regenerated.

607

U-BIT BINARY GROUP FLAG

Select the user bits to be used in the time code generated by the time
code generator.
000: Character set not specified.
001: 8-bit characters compliant with ISO 646 and ISO 2022.
010: Undefined.
011: Undefined.
100: Undefined.
101: SMPTE 262M page/line multiplex system.
110: Undefined.
111: Undefined.

611

TC OUTPUT PHASE IN EE MODE

Select the time code output mode for output from the TIME CODE OUT
connector in E-E mode.
mute: Mute the output.
thru: Output the time code input to the TIME CODE IN connector as it is.
v-in: Output the time code with the same phase as the input video signal

phase.

v-out: Output the time code with the same phase as the output video

signal phase.

612

TC OUTPUT MUTE IN SEARCH
MODE

Select whether to mute the output from the TIME CODE OUT connector
in jog/shuttle mode.
on: Mute.
off: Do not mute.

619

VITC

Specify whether or not to record the VITC generated by the internal time
code generator.
off: Do not record internally generated VITC.
on: Record internally generated VITC.