Site Preparation

10

An anti-tip bracket and hardware is provided with the inte-

grated unit. Placement of the anti-tip bracket is critical to

a stable installation. The anti-tip bracket must be installed

on a solid base.

If you are installing the unit in a space deeper than 24"

(610)

, be sure to locate the anti-tip bracket so that it

engages the unit properly. It is important that the anti-tip

bracket is placed 24"

(610)

from the front of the unit

(without panels) to the back of the anti-tip bracket.

IMPORTANT NOTE:

In some installations the subflooring

or finished floor may require angling the wood screws

used to fasten the anti-tip bracket to the back wall.

WOOD FLOOR APPLICATIONS

Use the six #12 x 2

1

/

2

" wood screws and the six

1

/

4

" flat

washers provided. Drill pilot holes

3

/

16

"

(5)

diameter

maximum, and make sure the screws penetrate through

the flooring material and into the wall plate a minimum of

3

/

4

"

(19)

. Make sure the screws hold tight. Refer to the

illustration below.

CONCRETE FLOOR APPLICATIONS

Use the two

3

/

8

" x 3

3

/

4

" concrete wedge anchors, two

#12 x 2

1

/

2

" wood screws and two

1

/

4

" flat washers

provided. Make sure the anchors and screws hold tight.

Refer to the illustration below.

Anti-Tip Bracket Installation

Make sure there are no electrical wires or plumbing

in the area which the screws could penetrate.

To prevent the unit from tipping forward and provide

a stable installation, the unit must be secured in place

with the anti-tip bracket provided with the unit.

Anti-Tip Bracket Placement

A

27"

(686)

Models

13

1

/

2

"

(343)

36"

(914)

Models

18"

(457)

A

A

SUBFLOORING

WOOD FLOOR

WALL PLATE

FINISHED
FLOORING

A

A

SUBFLOORING

CONCRETE

FLOOR

WALL PLATE

FINISHED
FLOORING

1

1

/

2

"

(38)

min

Wood floor.

Concrete floor.