Site preparation, Plumbing requirements – Sub-Zero IC-27FI User Manual

Page 9

Advertising
background image

Site Preparation

9

subzero.com/specs

Plumbing Requirements

For integrated models with an automatic ice maker, the

water supply line should be located through the floor or

back wall, within the shaded area shown in the illustra-

tions. Routing the line in these locations will avoid any

interference with the anti-tip bracket.

IMPORTANT NOTE:

Do not route the water supply line in

front of the compressor tray. The tray must be slid forward

for service.

The water supply line should be connected to the house

supply with an easily accessible shut-off valve between

the supply and the unit. Do not use self-piercing valves.

A saddle valve kit is available from your authorized

Sub-Zero dealer.

An in-line filter is required when water conditions have

a high sediment content.

A reverse osmosis system can be used provided there is

constant water pressure of 20 psi

(1.4 bar)

to 100 psi

(6.9 bar)

supplied to the unit at all times. In some cases,

a reverse osmosis water filter system may not be able to

maintain the minimum pressure consistently. A copper line

is not recommended for this application.

IMPORTANT NOTE:

All installations must meet local

plumbing code requirements.

3"

(76)

9"

(229)

3

/

4

"

(19)

FLOOR

2

1

/

2

"

(64)

FRONT VIEW

27"

(686)

models.

9"

(229)

6"

(152)

TOP VIEW

1

1

/

2

"

(38)

2

1

/

2

"

(64)

BACK
WALL

1

1

/

2

"

(38)

13

1

/

2

"

(343)

3"

(76)

FRONT VIEW

3

/

4

"

(19)

FLOOR

2

1

/

2

"

(64)

36"

(914)

models.

13

1

/

2

"

(343)

TOP VIEW

6"

(152)

1

1

/

2

"

(38)

BACK
WALL

2

1

/

2

"

(64)

1

1

/

2

"

(38)

Plumbing Requirements

Water Supply Line

1

/

4

" OD copper, braided stainless steel

or PEX tubing

Water Pressure

20–100 psi

(1.4–6.9 bar)

Excess Water Line for Connection

27"

(686)