Site preparation, Electrical requirements – Sub-Zero IC-27FI User Manual

Page 8

Advertising
background image

Site Preparation

8

Electrical Requirements

The electrical supply should be located within the shaded

area shown in the illustrations below. Follow the National

Electrical Code and local codes and ordinances when

installing the receptacle. A separate circuit, servicing only

this appliance is required. A ground fault circuit interrupter

(GFCI) is not recommended and may cause interruption of

operation.

IMPORTANT NOTE:

It is critical that the electrical outlet be

located within the shaded area shown so it does not inter-

fere with installation of the anti-tip bracket. It must be

flush with the back wall and positioned with the grounding

prong to the right of the thinner blades.

Electrical Requirements

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

Do not use an extension cord or two-prong adapter.

Do not remove the power supply cord ground prong.

The outlet must be checked by a qualified electrician

to be sure that it is wired with the correct polarity. Verify

that the outlet is properly grounded.