Status acquisition commands, Index request : 0x52 0x50 0x4d 0x44 (‘rpmd’), Tatus – Sony SRP-X500P User Manual

Page 20: Cquisition, Ommands, Index request, 2 status acquisition commands

Advertising
background image

SRP-X500P RS-232C Interface Manual

2.2 Status Acquisition Commands

The following commands are used to acquire the settings and the status of the SRP-X500P.

2.2.1 INDEX REQUEST : 0x52 0x50 0x4D 0x44 (‘RPMD’)

This command is used to read the index names of all input/output connectors of the SRP-X500P.
The parameter returned for this command are the index names entered in the index name input boxes in the
BLOCK screen of the SRP-X500P Manager.

Packet format

0x52 0x50 0x4D 0x44 0x0D

Return packet format

When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK
(0x41 (‘A’)) in the order shown below.
0x41

“

parameter” 0x0D

♦ Parameter

The parameter consists of 144 bytes of data in the order shown in the following table.

Byte Parameter

1st-8th

MIC 1/WL 1 INPUT INDEX

9th -16th

MIC 2/WL 2 INPUT INDEX

17th-24 th

MIC 3 INPUT INDEX

25th-32nd

MIC 4 INPUT INDEX

33rd-40 th

LINE INPUT INDEX

41st-48 th

AV/RGB INPUT A INDEX

49th-56th

AV/RGB INPUT B INDEX

57th –64th

AV/RGB INPUT C INDEX

65th-72nd

AV/RGB INPUT D INDEX

73rd-80th

AV/RGB INPUT E INDEX

81st-88th

SPEAKER OUTPUT 1 INDEX

89th-96th

SPEAKER OUTPUT 2 INDEX

97th-104th

SPEAKER OUTPUT 3 INDEX

105th-112nd

SPEAKER OUTPUT 4 INDEX

113rd-120th

LINE OUTPUT 1 INDEX

121st-128th

LINE OUTPUT 2 INDEX

129th-136th

LINE OUTPUT 3 INDEX

137th-144th

LINE OUTPUT 4 INDEX

• INDEX

The index names of the input/output channels are shown using 8 bytes of ASCII code.
If an index name is shorter than 8 bytes, space characters (0x20) are used as fill-in.