Parameter

The parameter consists of 16 bytes of data in the order shown in the following table.

Byte Parameter

1st

MIC 1/WL 1 INPUT LEVEL METER

2nd

MIC 2/WL 2 INPUT LEVEL METER

3rd

MIC 3 INPUT LEVEL METER

4th

MIC 4 INPUT LEVEL METER

5th

LINE INPUT L LEVEL METER

6th

LINE INPUT R LEVEL METER

7th

AV/RGB INPUT L LEVEL METER

8th

AV/RGB INPUT R LEVEL METER

9th

SPEAKER OUTPUT 1 LEVEL METER

10th

SPEAKER OUTPUT 2 LEVEL METER

11th

SPEAKER OUTPUT 3 LEVEL METER

12th

SPEAKER OUTPUT 4 LEVEL METER

13th

LINE OUTPUT 1 LEVEL METER

14th

LINE OUTPUT 2 LEVEL METER

15th

LINE OUTPUT 3 LEVEL METER

16th

LINE OUTPUT 4 LEVEL METER

LEVEL METER (1st-16th byte)

Indicates the level meter reading (in VU units).
The parameter and the level meter reading are as shown in the following table.

Level meter
reading

Level

meter

reading

Less than -30

0x30 (‘0’)

-4

0x39 (‘9’)

-30

0x31 (‘1’)

-3

0x3A (‘:’)

-20

0x32 (‘2’)

-2

0x3B (‘;’)

-15

0x33 (‘3’)

-1

0x3C (‘<‘)

-10

0x34 (‘4’)

0

0x3D (‘=‘)

-8

0x35 (‘5’)

1

0x3E (‘>‘)

-7

0x36 (‘6’)

2

0x3F (‘?’)

-6

0x37 (‘7’)

3 or more

0x40 (‘@’)

-5 0x38

(‘8’)