Supervisor menus – Siemens ProLINE-RoadRunner User Manual

Page 11

Advertising
background image

9

ProLINE-RoadRunner Operator’s Guide

A

View the Supervisor Menus by
inserting a PCMCIA card with
supervisor authority.
(The menus on this page and the
next two pages are in addition to the
Operator Menus.)

Supervisor (Administrator)
authorization is set in TaskLink. For
more information, refer to the
TaskLink Help Menu.

Version 5.11.00 menus shown.

A (

) indicates the currently

selected item.

A (

X

) indicates the current cursor

position.

• HOME sends the

PNP Head to the

Home position.

• Light gray shaded

fields cannot be

changed.

M a i n M e n u

Job
Advance Pocket
Align Pocket
Purge
Socket
Home
Operation
System
Robot Diagnostics
Programmer Diags
Event Log

J o b

View

Job Name
Device: E28F320
Checksum: 3FC00000
Mfg: INTEL
Adapter: PA-G021
Prec: 621-0086-005
Act: 644-0016-001

Results

Passed: 992
Failed: 4
System Yld: 98.7
Prgrmr Yld: 99.6
Handler Yld: 99.5
Parts/Hour: 255
MCBI: 201
Skt 1 Yld: 99.9
Skt 2 Yld: 100
Skt 3 Yld: 100
Skt 4 Yld: 100
Skt Cycles: 249

End
Select

X Job 1

y

Job 2

End of List

S o c k e t

Socket 1: Enabled
Socket 2: Enabled
Socket 3: Enabled
Socket 4: Enabled
Adapter Statistics

Reset Clean Count
Clean Count
Clean Alert: 3500
No: 22113204
Mfg: 09/23/02
Actuations:1055
Adptr. Life: 10000
Insertions: 4220
Pass: 4202
Fail: 16
Yld: 99.5
Socket 1
Insertions: 1055
Pass: 1053
Fail: 2
Yield: 99.8
Socket 2 [Same as 1]
Socket 3 [Same as 1]
Socket 4 [Same as 1]