Storing Cartridges

Storing Cartridges

When storing a cartridge:

Do not take a cartridge out of its protective wrapping until you are ready to
use it. Use the tear string, not a sharp instrument, to remove the wrapping.

Store cartridges in a clean environment that duplicates the conditions of the
room in which they are used.

Before using a cartridge, make sure that it has been in its operating
environment for at least 24 hours.

Cleaning the Cartridge Exterior

CAUTION:
Possible equipment damage:
The following solvents can damage the
cartridge. Do not use them to remove labels or to clean cartridges:
acetone, trichloroethane, toluene, xylene, benzene, ketone, methylethyl
ketone, methylene chloride, ethyldichloride, esters, ethyl acetate, or
similar chemicals.

Wipe all dust, dirt, and moisture from the cartridge with a lint-free cloth.

Use StorageTek Tape Cleaner Wipes, PN 4046289-01, to clean the cartridges.
These wipes are saturated with isopropyl alcohol. Do not let any solution touch
the tape or get inside the cartridge.

Using Cleaning Cartridges

Cleaning cartridges have a VOLSER prefix of DG CLN or CLNxxx. These
cartridges cannot be used as scratch cartridges or initialized by software utilities.

When a transport needs to be cleaned, the 9740 and CTU interact automatically;
no host software interaction is required. During a dismount, the 9740 software
polls the CTU to determine if the transport needs to be cleaned. If it does, the
hand removes a cleaning cartridge from its cell and inserts it into the transport.

If the LSM has no cleaning cartridges, you are prompted to enter a cleaning
cartridge into the CAP.

CAUTION:
Do not re-enter a cleaning cartridge that has been ejected from an LSM.
When you enter a cleaning cartridge, the software considers it to be new
and sets the usage counter to zero.