Instructions for the installer, 2 regulation for lpg – Smeg A1.1K User Manual

Page 10

Advertising
background image

Instructions for the installer

44

3.2 Regulation for LPG

Loosen screw A and push air regulator B to the bottom.
With a 7 mm wrench, remove nozzle C and replace it with the proper one
(follow the instructions on the reference tables for the type of gas to be
used). The torque wrench setting of the nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator B until reaching distance “X” shown
in the table in paragraph “3.4 Regulation of primary air”. Lock regulator B
by tightening screw A.







Burner

Rated

heating

capacity

(kW)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

mm

1/100

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1.05

48

30

380

76

75

Semi rapid

1.65

62

30

380

120

118

Rapid

2.55

76

45

800

185

182

Ultra rapid

3.25

85

65

1400

236

232

Fish pan

1.9

65

48

800

138

136

Advertising