Instructions for the installer, Adaptation to different types of gas – Smeg A1.1K User Manual

Page 9

Advertising
background image

Instructions for the installer

43

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.

The cooking hob of the cooker is inspection-tested for use with G 20
natural gas
at a pressure of 20 mbars. If used with other types of gas,
you have to replace the nozzles and regulate the primary air to the
burners. Then regulate the minimum flame on the gas taps. For nozzle
replacement and burner adjustment you must raise the cooking hob as
described in the following paragraph.

3.1 Raising of cooking hob

Remove the grids, first the middle one then the ones at the sides; remove
all the burner caps, the flame cap crowns and the burners.
1. Remove the programmer buttons;
2. Remove the knobs;
3. Unscrew the front panel fixing screws and remove it after

disconnecting the thermostat tell-tale light faston;

4. Loosen the screws of the hinge on the back of the cooker;
5. Raise the surface from the front end;
6. Place the surface support brackets in the front groove of the side;
7. Proceed to replacement of the burner nozzles in accordance with the

appropriate gas table;

8. Adjust the primary air as described in paragraph “3.2 Regulation for

LPG ”;

9. After adjustment, fully tighten the fixing screws.