Instructions for the installer

46

4. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph “3.1 Raising of
cooking hob”.

After adjustment to a different kind of gas from the one for which the
cooker has been tested, replace the plate inside the storage
compartment with one corresponding to the new kind of gas. This plate
can be obtained from your nearest Authorised Assistance Centre.

4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum.
Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.


4.2 Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model).
The diameters of the by-passes for each burner are given in table “3.2
Regulation for LPG ”.


4.3 Arrangement of burners on cooking hob

BURNERS


1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra

rapid

5 Fish

pan