Instructions for the installer

45

3.3 Regulation for natural gas

The cooking hob has been inspected for G 20 natural gas at a pressure
of 20 mbar. To allow the unit to work with this type of gas, perform the
same operations described in paragraph “3.2 Regulation for LPG ”, but
choose the nozzles and regulate the primary air for natural gas, as shown
in the following table and in paragraph “3.4 Regulation of primary air”.



Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary

1.05

73

380

Semi rapid

1.65

92

380

Rapid

2.55

115

700

Ultra rapid

3.25

130

1200

Fish pan

1.9

95

750


3.4 Regulation of primary air

Referred to distance “X” in mm.

BURNER

G20

20 mbar

G30/G31

28/37 mbar

Auxiliary

2.5

2.5

Semi rapid

1

1.5

Rapid LH

1.5

2.5

Rapid RH

1.5

2.5

Ultra rapid

1.5

2.5

Fish pan

2.5

3