Sony HDW-M2000 User Manual

Page 115

Advertising
background image

Chapter 9

Setup Menus

Chapter 9 Setup Menus

9-19

Menu items in the range 600 to 699, relating to the time code generator (Continued)

602

VITC POSITION SEL-2

In 59.94 Hz mode
Select a line to insert the VITC in. (For SD output)
12H to 18H to 20H: Select any line from 12 to 20.

Note

You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.

In 50 Hz mode
Select a line to insert the VITC in. (For SD output)
9H to 21H to 22H: Select any line from 9 to 22.

Note

You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.

Item number

Item name

Settings

603

ID CODE PRESET

Select whether or not to set the ID code.
OFF : Do not set the ID code.
ON: Set the ID code.

To set the ID code:
Press the F5 (SET) button with this menu item displayed in the menu display, to
enter the ID code setting mode. You can then set the user ID digit by digit using
the

T and t buttons for digit selection. When all required digits have been set

correctly, press the F5 (SET) button again to save the ID code and exit from the
ID code setting mode.

604

ID CODE SW

Select whether or not to record the ID code set using menu item 603 in the user
bits.
OFF : Record the normal data in the user bits.
ON: Record the ID code in the user bits.

605

TCG REGEN MODE

Select the signals to be regenerated when the time code generator is in the
regeneration mode (i.e., when the function menu item PR/RGN (F2) is set to LTC
or VITC, or the unit is in automatic edit mode).
TC&UB : Both the time code and user bit signals are regenerated.
TC: Only the time code signal is regenerated.
UB: Only the user bit signal is regenerated.

606

TC OUTPUT SIGNAL IN
REGEN MODE

Select the signal output from the TIME CODE OUT connector during normal (

×1)

speed playback:
TAPE : During tape playback, the playback time code signal is output without

regeneration.

REGEN : The playback time code is output after regeneration.

607

U-BIT BINARY GROUP
FLAG

Select whether to generate time code automatically.
000 : Character set not specified
001: 8-bit characters compliant with ISO 646 and ISO 2022
010: Undefined
011: Undefined
100: Undefined
101: SMPTE 262M page/line multiplex system
110: Undefined
111: Undefined

(Continued)