The voltage derating factor should be as great as possible. Under normal conditions, the operating

voltage should be reduced to 50% or less of the rating. It is recommended that the operating
voltage be 30% or less of the rating, particularly when the tantalum capacitors are used in a low-
impedance circuit (see Figs. 1, 2, and 3).

For circuits in which a switching, charging, discharging, or other momentary current flows, it is

recommended that the operating voltage be 30% or less of the rating, with a resistor connected in
series to limit the current to 300 mA or less.

When the tantalum capacitors are to be used at an ambient temperature of higher than 85℃, the

recommended operating range shown in Fig. 3 should not be exceeded.

SCL Series

APPLICATION MANUAL

OPERATING VOLTAGE

The operational attentions to the use of the tantalum capacitors are as follows:

- Electrical

- Environmental

- Conditions for mounting on equipment and circuit boards

- Mechanical vibration, shock

If the tantalum capacitors are used without satisfying any one of these conditions, the probability of
short-circuiting, leakage current, ignition or other problems to occur increases. To avoid such
problems, observe the following precautions when using the tantalum capacitors.

-

Power

supply
circuit

~

+

+

Fig. 1

Power supply filter

IC

+

-

+

Fig. 2

Power supply bypass

OPERATING TEMPERATURE

-40 -20 0 20 40 60 85 100 125

-55

100

80

60

40

20

0

Fig. 3