SCL Series

RELIABILITY TEST CONDITION

NO

ITEMS

TEST CONDITION

PERFORMANCE

1

RATED DC VOLTAGE

-55℃ ~ +85℃

2.5∼35V

2

CAPACITANCE

MEASURING FREQUENCY : 120±12Hz
MEASURING VOLTAGE : 0.5Vrms + 0.5∼2V DC
MEASURING CIRCUITS : EQUIVALENT SERIES

CIRCUIT

CAPACITANCE RANGE
0.1∼330㎌
TOLERANCE ON CAP.
±

10%, ±20%

3

TANGENT OF LOSS

ANGLE

MEASUREMENT SHALL BE MADE UNDER THE

SAME CONDITIONS AS THOSE GIVEN FOR THE
MEASUREMENT OF CAPACITANCE.

4

LEAKAGE CURRENT

THE RATED DC VOLTAGE SHALL BE APPLIED

TO TERMINALS ACROSS THE TEST CAPACITOR
Cx, BY THE METHOD AS SHOWN BELOW. THE
LEAKAGE CURRENT SHALL THEN BE
MEASURED AFTER CHARGE FOR 5 MIN.

MEASURING CIRCUITS

WHERE
R

S

: STANDARD RESISTOR(PROTECTIVE R :1KΩ)

: DC VOLTMETER OR ELECTRONIC

VOLTMETER

S1 : DC POWER SUPPLY SWITCH
S2 : PROTECTIVE SWITCH FOR A AMMETER
C

X

: TEST CAPACITOR
: DC AM-METER FOR LEAKAGE CURRENT

0.01CV or 0.5㎂
WHICHEVER IS GREATER

5

IMPEDENCE

AC VOLTAGE(0.5Vrms OR LESS) OF A

FREQUENCY SPECIFIED ON NEXT PAGE SHALL
BE APPLIED AND THE VOLTAGE DROP
ACROSS CAPACITOR TERMINALS SHALL BE
MEASURED
THE IMPEDANCE SHALL BE CALCULATED BY
THE FOLLOWING EQUATION.

WHERE
E : VOLTAGE DROP ACROSS THE CAPACITOR
TERMINALS
I : CURRENT FLOWING THROUGH THE
CAPACITOR

(FREQUENCY : 100±10kHz)

V

A

+

-

R

S

S

1

S2

V

C
x

A

+

-

Impedance Z

E

I

=