3-2. outdoor unit – Sanyo C0951 User Manual

Page 15

Advertising
background image

12

PTC Thermistor

PS2A E20-470

Resistance

(at 77°F (25°C))

47 ± 25%

2-3-2. Outdoor Unit

(1) Outdoor unit C0951 / CL1251

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Transformer (TR)

ATR-T4

Rating

Primary

AC 115V, 60Hz

Secondary

DC 19V, 0.5A

Capacity

5VA

Thermistor (Air temp.)

DTNTKS132B

Resistance

k

32°F (0°C) 15 ± 2%

PTC Thermistor

PS2A E20-470

Resistance

(at 77°F (25°C))

47 ± 25%

(2) Outdoor unit CL0951 / CL1251

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Transformer (TR)

— / ATR-T5

Rating

Primary

AC 230V, 60Hz

Secondary

— / DC 19V, 0.5A

Capacity

5VA

Thermistor (Air temp.)

— / DTNTKS132B

Resistance

k

32°F (0°C) 15 ± 2%

(3) Outdoor unit C1852 / CL1852

Heater Relay

— / HH62S

Coil rating

AC 220–240V

Coil resistance

(at 68°F (20°C))

Contact rating

AC 250V, 10A

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Heater Relay

HH62S

Coil rating

AC 110–120V

Coil resistance

(at 68°F (20°C))

Contact rating

AC 250V, 10A

000-215 SM (1-56) 7/5/00 2:49 PM Page 12

Advertising
This manual is related to the following products: