Electrical data, 1. electrical characteristics – Sanyo C0951 User Manual

Page 29

Advertising
background image

26

6. ELECTRICAL DATA

6-1. Electrical Characteristics

Cooling

(1) Indoor unit

KS0951

Outdoor unit

C0951 / CL0951

115V single-phase 60Hz

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

115V single-phase 60Hz

Rating conditions

Running amp.

A

0.40

0.655

7.7

8.8

Power input

kW

0.034

0.075

0.79

0.90

Full load conditions

Running amp.

A

0.4

0.655

9.4

10.5

Power input

kW

0.034

0.075

1.04

1.15

Rating conditions:

Indoor air temperature

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

Outdoor air temperature

95°F (35°C) D.B.

Full load conditions: Indoor air temperature

95°F (35°C) D.B. / 70°F (21.2°C) W.B.

Outdoor air temperature

115°F (46.1°C) D.B.

(2) Indoor unit

KS1251

Outdoor unit

C1251 / CL1251

115V single-phase 60Hz

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

115V single-phase 60Hz

Rating conditions

Running amp.

A

0.40

0.704

9.8

10.9

Power input

kW

0.034

0.081

1.09

1.20

Full load conditions

Running amp.

A

0.4

0.704

12.2

13.3

Power input

kW

0.034

0.081

1.41

1.52

Rating conditions:

Indoor air temperature

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

Outdoor air temperature

95°F (35°C) D.B.

Full load conditions: Indoor air temperature

95°F (35°C) D.B. / 70°F (21.2°C) W.B.

Outdoor air temperature

115°F (46.1°C) D.B.

(3) Indoor unit

KS1852

Outdoor unit

C1852 / CL1852

230 / 280V single-phase 60Hz

Indoor Unit

Outdoor Unit

Complete Unit

Fan Motor

Fan Motor

Compressor

Performance at

230 / 208V single-phase 60Hz

Rating conditions

Running amp.

A

0.25 / 0.23

0.498 / 0.465

7.1 / 7.7

7.8 / 8.4

Power input

kW

0.047 / 0.045

0.113 / 0.095

1.56 / 1.53

1.72 / 1.67

Full load conditions

Running amp.

A

0.25 / 0.23

0.498 / 0.465

8.6 / 9.5

9.3 / 10.2

Power input

kW

0.047 / 0.040

0.113 / 0.095

1.93 / 1.96

2.09 / 2.10

Rating conditions:

Indoor air temperature

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

Outdoor air temperature

95°F (35°C) D.B.

Full load conditions: Indoor air temperature

95°F (35°C) D.B. / 70°F (21.2°C) W.B.

Outdoor air temperature

115°F (46.1°C) D.B.