Alarm setting – Speco Technologies PC Pro Series User Manual

Page 127

Advertising
background image

119

Alarm Setting

In the Alarm Setting dialog box, click Add to insert and set new alarm setting, click Delete to
remove the selected alarm setting, click OK to exit and save the setting, Cancel to exit without
saving, and Default to revert back to original factory setting.

(1)

(2)

(3)

(4)

(5)

(6)

(7)

To set the Alarm Setting:

1. Click

Add

to insert and set a new alarm setting. Click the items in the (7) Alarm Setting List,

if you want to modify the alarm setting.

2. In

(1) Alarm Setting number/Name/Description

, display the selected alarm setting number

in the list below. Enter alarm name and description.

3. In

(2) Enable Time

, the number from 00 to 23 represent the time in 24-hour clock. Select the

time and click the block you want to activate or deactivate the alarm function. When it is
deactivated the color of the block turns white.

4. In

(3) Conditions

, you can set “Trigger if any” to activate if it falls to one of the conditions or

Trigger if all” to activate if it falls to all conditions.

-

In Camera section, select and click on the camera number (01 to 16) in Motion
Detected

and Video Loss to set the condition for the system to alarm.

- In

Missing and Suspicious Object Detected

, click the camera number (01 to 16) and

select the certain object on the screen (right click on camera number for detailed
setting)), and when the certain object is missing or doubtful, the system will alarm. (see
also

Chapter 4.9.12

) In Scene Change, when the camera has been moved, the system

will alarm, too.

- In

Voice Detection

, click the camera number (01 to 16) to the system to alarm when

detect the abnormal voice.

5. In

(4) Sensor

, select and click on the sensor number (use W and X to select the sensor) to

set the condition for the system to alarm. If the sensor normal status is high, set the sensor
condition to low (see

Chapter 4.7 step #4

).

- Enable/disable

the

Abnormal Event

check box, to set the condition of the event for

system to alarm.

Normal Reboot:

when the DVR system reboot without abnormal condition, the

system will send out the alarm message.

Abnormal Reboot:

when the DVR system reboot in irregular condition, the system

will send out the alarm message.

Recording is switched off:

when the recording has been stopped, the system will

Advertising