Menu items in the range 100 to 199, relating to the control panels (Continued)

Item number

133

134

135

136

Item name

TELE-FILE CONTROL
MODE

TELE-FILE MENU AUTO
POPUP

TELE-FILE THREAD
COUNTER CLEAR MODE

TELE-FILE IN OUT INPUT
CONTINUE

Settings

Selects the device used for data modification operations in the Tele-File menu.
CONTROL PANEL : Operate with the control panel of this unit.
REMOTE: Operate with remote devices connected to connectors such as

REMOTE1, REMOTE2, and RS-232C.

Selects whether to open the Tele-File menu automatically when a cassette with a
Tele-File label is loaded. However, this is valid only when the function menu is
HOME, HOME2, or page 1 to 5.
OFF : Do not open the Tele-File menu automatically.
ON: Open the Tele-File menu automatically.

Selects whether to clear the thread counter when formatting a Tele-File.
NOT CLEAR : Do not clear the thread counter.
WHEN FORMAT: Clear the thread counter.

Selects whether to continuously input log (IN and OUT point) data in the Tele-File
menu screen.
OFF : Do not continuously input log (IN and OUT point) data.
ON : Continuously input log (IN and OUT point) data.

Menu items in the range 200 to 299, relating to the remote control interface

Item number

201

202

211

Item name

PARA RUN

CF FLAG (DVW-M2000P/
2000P only)

REMOTE1 PORT

Settings

Select whether or not to use synchronized operation for two or more VTRs.
DIS : No synchronized operation
ENA: Use synchronized operation

Note

To use synchronized operation for two or more VTRs, set item 201 to “ENA” on
all of the VTRs.

Select the mode for locking to the color framing sent from the remote controller.
8F : Eight-field locking mode
4F/8F: Four- or eight-field locking mode

Select how to use the REMOTE 1-IN(9P) and REMOTE 1-OUT(9P) connectors
on the connector panel.
i&o : Both the IN and OUT connectors are effective whether in local or remote

mode.

in: Only the IN connector is effective whether in local or remote mode.
out: Only the OUT connector is effective whether in local or remote mode.
panel: Allows you to select i&o, in, or out using the function menu.

Note

When selecting “panel”, first define user-defined function key RMT1 in the
HOME2 page.

On how to define user-defined function keys in the HOME2 page, refer to the
Maintenance Manual Volume 1.