1 recording – Sony DVW-2000 User Manual

Page 46

Advertising
background image

4-1

Recording

Chapter 4

Recording and Playback

4-4

Chapter 4

Recording and Playback

To synchronize the internal time code
generator to an external signal

Use this method to synchronize the time code
generators of a number of VTRs, or to record the
playback time code signal from an external VTR
without deterioration of the signal waveform.
In this case the RUN and DF settings are ignored. You
can synchronize the internal time code generator to
either of the following external time codes.
• The time code output (LTC) of an external time code

generator or external VTR connected to the TIME
CODE IN connector of the unit

• The time code (VITC) present in a video signal input

to the unit

• The time code (SMPTE RP188) present in an SDI

signal input to the unit

To synchronize the internal time code generator to an
external signal, use the following procedure.

1

• When synchronizing to an external time code

output (LTC):
Connect the time code output of the external time
code generator or external VTR to the TIME
CODE IN connector.

• When synchronizing to the time code (VITC) in

an input video signal:
With the VID.IN in function menu HOME page,
select an input video signal containing VITC.

• When synchronizing to the time code (SMPTE

RP188) in an SDI signal:
With the VID.IN in function menu HOME page,
select SDI.

2

Perform the following settings in function menu
page 1.
• When synchronizing to an external time code

output (LTC) or the time code (VITC) in an input
video signal:
TCG (F1): EXT
TCG (F2): REGEN
VITC: ON (when recording VITC)
TCR: LTC or VITC according as you are

synchronizing to LTC or VITC (If set to
AUTO, LTC is used.)

• When synchronizing to the time code (SMPTE

RP188) in an SDI signal:
TCG (F1): RP188
TCG (F2), VITC, TCR: Any setting

Note

When the TCG (F1) is set to RP188, when settings
of the TCG (F1) and VID.IN conflict with each
other, or when the input signal selected with the
VID.IN is not present, the TCG (F1) setting
display flashes.

This starts the internal time code generator running
in synchronization with the external time code
generator.
Once the internal time code generator is
synchronized with the external time code
generator, even if the external time code generator
connection is removed, the internal time code
generator continues to run.

TIME CODE IN connector

Z

1,2

TIME CODE

IN

OUT

1

Advertising