Trigger mode, Trigger mode -8, Trigger mode parameter # 8ah – Symbol Technologies DS6707 User Manual

Page 50: Time delay to low power mode (continued)

Advertising
background image

4 - 8

DS6707 Digital Imager Scanner Product Reference Guide

Trigger Mode

Parameter # 8Ah

Select one of the following trigger modes for the digital imager scanner:

Level - A trigger pull activates decode processing. Decode processing continues until the bar code is
decoded, the trigger is released, or the Decode Session Timeout is reached.

Blink - This trigger mode is used in hands-free (Intellistand) mode. The digital imager scanner activates
decode processing when it detects a bar code in its field of view. Decoding range is reduced in this mode.

Auto Aim- This trigger mode turns on the red laser aiming pattern when the digital imager scanner
senses motion. A trigger pull activates decode processing. After 2 seconds of inactivity the red laser
aiming pattern automatically shuts off.

Time Delay to Low Power Mode (continued)

15 Minutes

(2Bh)

1 Hour

(31h)

Level

(00h)

Blink
(07h)

*

Auto Aim

(09h)