Kodak Ektagraphic III PAINTED and NON-PAINTED PROJECTORS J-E PLUS User Manual

Page 50

Advertising
background image

SERVICE MANUAL

50

30APR96 – SM4530-1

TIMER does not operate

1. Check the VARIABLE RESISTOR for

correct operation and install a new part if
necessary.

2. Move the TIMER BUTTON forward and

backward; use a DVM to check for changes
in W.

3. Energize the projector and move the TIMER

to “S”.

• Check the voltages on CR3, Q3, and

Q4, see the voltage table.

DARK SHUTTER SWITCH does not operate

1. Energize the projector and release the

DARK SHUTTER to allow projection.

2. Check for continuity between PINS 4 and 5

on the SPECIAL APPLICATIONS PLUG.

3. Press the “FORWARD” or “REVERSE”

BUTTONS to close the DARK SHUTTER.

4. In the closed position, the DVM should

measure 0 W.

5. If this procedure does not correct the

malfunction, install a new DARK SHUTTER
SWITCH.

ZERO POSITION SWITCH does not operate

1. Deenergize the projector.

2. Check for continuity between PINS 1 and 3

on the SPECIAL APPLICATIONS PLUG.

3. Install a SLIDE TRAY.

4. Rotate the SLIDE TRAY to engage the

ZERO POSITION SWITCH, the DVM
should measure 0 W.

5. If the W measurement is not correct, see

the adjustment for the ZERO POSITION
SWITCH. Install a new ZERO POSITION
SWITCH if necessary.

After the FOCUS MOTOR energizes and
moves, the FOCUS MOTOR oscillates.

1. Remove R3 and install a new 68K W 1/4 W

RESISTOR (part 220040).

2. If there is still a malfunction, install a new

PHOTOCELL.

Malfunction

Check

Advertising