Kodak Ektagraphic III PAINTED and NON-PAINTED PROJECTORS J-E PLUS User Manual

Page 53

Advertising
background image

Diagnostics

SM4530-1 – 30APR96

53

AUTO FOCUS MOTOR operates continually

1. Install the TARGET SLIDE TL-3002 in the

GATE MECHANISM.

2. Check that the alignment of the TARGET

and NULL is correct. If not, see the
Adjustments section.

3. Check for a light leak:

• Install a different LAMP MODULE

ASSEMBLY. If the FOCUS MOTOR
stops operating continually, install a
new LAMP MODULE ASSEMBLY.

4. Check that the voltages across the

PHOTOCELL are correct. The voltage from
1 to 2 is 14.5 V ac. The voltage from 2 to 3
is 14.5 V ac. The voltage from 1 to 3 is 29
V ac.

5. Check that the PHOTOCELL HOUSING

has 2 FILTERS.

6. Install a new PHOTOCELL.

7. Check the components on the CIRCUIT

BOARD for damage.

AUTO FOCUS MOTOR operates continually in
forward only or reverse only and does not
operate (stops) in the null position.

1. Check that the wires of the AUTO FOCUS

MOTOR are in the correct position; the blue
wire goes to the mark on the AUTO FOCUS
MOTOR.

AUTO FOCUS adjusts after REMOTE use

1. Do the adjustment for the CLAMP LEVER

ASSEMBLY.

Malfunction

Check

Advertising