Focus malfunctions – Kodak Ektagraphic III PAINTED and NON-PAINTED PROJECTORS J-E PLUS User Manual

Page 51

Advertising
background image

Diagnostics

SM4530-1 – 30APR96

51

Focus Malfunctions

Malfunction

Check

No manual focus

1. Check the FOCUS SHAFT SPRING for the

correct tension.

2. Check the LENS SUPPORT SPRING for

correct tension.

3. Check the LENS DRIVE GEAR on the

FOCUS SHAFT ASSEMBLY for damage
and install a new part if necessary.

No remote focus (Non Auto Focus models)

1. Check the REMOTE CORD for damage;

use a REMOTE CORD that has no
damage.

2. Actuate and hold the REMOTE CONTROL.

3. Check that the voltage across the FOCUS

MOTOR is 8.5 V AC. If the voltage is
correct, install a new FOCUS MOTOR.

Check that the secondary voltage on the MAIN
MOTOR is correct.

No remote focus, RACK SOLENOID
ASSEMBLY operates (Auto Focus Models)

1. Check that the REMOTE CORD operates

correctly; use a REMOTE CORD you know
is good (EC 3).

2. Actuate and hold the REMOTE CONTROL.

3. Check that the voltage across the FOCUS

MOTOR is 8.5 V AC. If the voltage is
correct, install a new FOCUS MOTOR.

4. Check the AUTO FOCUS SWITCH

ASSEMBLY for correct operation.

5. Check the secondary voltages on the MAIN

MOTOR.