Replacing the cycle solenoid assembly, Installing the cycle solenoid assembly – Kodak Ektagraphic III PAINTED and NON-PAINTED PROJECTORS J-E PLUS User Manual

Page 12

Advertising
background image

SERVICE MANUAL

12

30APR96 – SM4530-1

Replacing the CYCLE SOLENOID ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedures for the LOWER

HOUSING ASSEMBLY and the MOTOR.

[3] Cut and remove the necessary WIRE TIES.

[4] Disconnect the 2 wires from the CYCLE

SOLENOID on the SMALL CIRCUIT BOARD.

[5] Pull the SMALL CIRCUIT BOARD up.

[6] Remove the

Torx SCREW (for N.P. models) (or

Hex SCREW for Painted Models) from the WORM
PULLEY SHAFT.

[7] Move the TAB on the WORM PULLEY

ASSEMBLY out of the MECHANISM ASSEMBLY.

[8] Lift and remove the WORM PULLEY ASSEMBLY.

[9] Remove the 2

Torx 1/4 in. SCREWS from the 2

CYCLE SOLENOID GROMMETS.

[10] Pull the CYCLE SOLENOID ASSEMBLY up and

out.

[11] If necessary, remove the CYCLE SOLENOID

PLUNGER ASSEMBLY.

Installing the CYCLE SOLENOID ASSEMBLY

Important

Do the adjustment for the CYCLE SOLENOID ASSEMBLY. See the Adjustments section.

[1] Do the replacement procedure for the CYCLE SOLENOID ASSEMBLY in reverse order.

A100_0017GA

PLUNGER

SOLENOID

CYCLE

CYCLE SOLENOID

SCREW (2)

A100_0017GCA

Advertising