Connecting the Sine/Cosine Interface

(Optional)

The GyroTrac ADCU sine/cosine interface provides the following
outputs:

sine

cosine

inverse sine

inverse cosine

reference voltage

Because the reference voltage is a reference output, not an input,
connecting this output to another reference output from an
autopilot or other system will cause problems.

In this case, connect the following wires from the autopilot (or
other system) to the green ADCU terminal strip connector:

Autopilot/Other System Wire

Terminal Connector

Sine

12

Cosine

10

Internal Power Ground

7

(not chassis ground!)

Reference (INPUT)

8 (KVH Output)

DO NOT connect the autopilot or other system to the ADCU reference
output (ADCU terminal 8) if the autopilot has its own internal
reference. Review the user’s manual for the selected equipment.

Installation

54-0147

35

1

2

11

10

9

8

7

6

12

5

4

3

Sine

Cosine

Ref

Ground

Sine (inverted)

Cosine (inverted)

Green Label

Table 2-6
GyroTrac/Autopilot Sine/Cosine
Wiring Arrangement

Before connecting the Autopilot
internal ground to ADCU terminal 7,
use a low impedance voltmeter to
make certain that there is no DC
voltage between the two terminals.
A DC surge could damage one or
both systems.

The sine/cosine reference voltage is
an OUTPUT, not an INPUT.
Connecting this output to the
reference output for an autopilot or
other system can cause problems.
This section explains how to resolve
most issues.

Figure 2-26
Sine/Cosine ADCU Wiring