Kenwood TS-570S TS-570D User Manual

Page 50

Advertising
background image

44

10 MEMORY FEATURES

Memory Channel Lockout

You can lock out Conventional memory channels
that you prefer not to monitor during Memory Scan.
Memory Scan is described in the next chapter.

1 Press [M/V] to enter Memory Recall mode.

2 Turn the MULTI/CH control, or press Mic [UP] or

[DWN] to select a memory channel.

3 Press [CLR].

Release [CLR] immediately. Pressing it for
more than approximately 2 seconds erases
the contents of the memory channel.

A dot appears beside the right-most digit of
the memory channel number to indicate the
channel has been locked out.

Repeatedly pressing [CLR] adds and
removes the channel from the scan list.

QUICK MEMORY

Quick memory is designed for quickly and temporarily
saving data without specifying a particular memory
channel. Use Quick memory to store data that you will
not need during future operating sessions. For
example, as you tune across the band looking for DX, it
is convenient to store stations that you want to contact.
You can quickly jump between several different
memory channels as you monitor them.

This transceiver provides five Quick memory channels
that can store the following data:

STORING INTO QUICK MEMORY

Each time you store a new frequency, all previously
stored frequencies are bumped to their next respective
Quick memory channel. When all five memory
channels contain frequencies, storing one more
frequency bumps the contents of memory channel 5 off
the stack (data lost).

You can store data in Quick memory only when using
VFO frequencies for both transmitting and receiving.

1 Select the frequency, mode, etc.

2 Press QUICK MEMO [M.IN].

Each time [M.IN] is pressed, the current VFO
data is written to Quick memory.

Note:

When RIT or XIT is ON, this ON status and the offset also

will be stored.

TX frequency

Mode for TX

Microphone gain

Keying speed

Break-in delay time

VOX ON/OFF

Noise Blanker ON/OFF

CTCSS ON/OFF

Fine Tuning ON/OFF

XIT ON/OFF

RX frequency

Mode for RX

RIT/XIT offset

Transmit power

VOX delay time

Receive filter bandwidth

1

Speech Processor ON/OFF

Subtone ON/OFF

1 MHz Step ON/OFF

RIT ON/OFF

1

DSP SLOPE control settings are not stored.

24.911

14.235

18.111

7.082

3.545

21.200

24.911

14.235

18.111

7.082

10.103

Memory 1

Memory 2

Memory 3

Memory 4

Memory 5

Memory 1

Memory 2

Memory 3

Memory 4

Memory 5

Memory 1

Memory 2

Memory 3

Memory 4

Memory 5

21.200

24.911

14.235

18.111

Advertising