Vs-3 voice synthesizer unit, 14 installing options – Kenwood TS-570S TS-570D User Manual

Page 64

Advertising
background image

58

VS-3 VOICE SYNTHESIZER UNIT

CAUTION:

SWITCH OFF THE POWER AND UNPLUG THE DC

POWER CABLE BEFORE BEGINNING INSTALLATION.

1

Remove the bottom case (8 screws).

2

Hold the VS-3 unit with the component side facing
inward, and insert the VS-3 connector into the
transceiver CN16 connector.

3

Replace the bottom case (8 screws).

Note:

The VR8 allows you to adjust the volume for voice

announcement. Use only when the volume level is too low or too
high.

YK-88C-1/ YK-88CN-1/ YK-88SN-1
FILTERS

CAUTION:

SWITCH OFF THE POWER AND UNPLUG THE DC

POWER CABLE BEFORE BEGINNING INSTALLATION.

1

Remove the 2 screws from the bottom cover of the
transceiver.

2

Remove the bottom cover.

14 INSTALLING OPTIONS

3

Remove the 2 screws from the OPTION FILTER
section of the transceiver PC board.

4

Align the pins of the transceiver CN8 and CN9
connectors with the two connectors on the filter.

Take care to properly align the pins.

5

While holding the filter, carefully push down until the
filter snaps into place.

6

Re-install the 2 screws that you removed in step 3.

7

Replace the bottom cover (2 screws).

Note:

After installing the filter, be sure to select the appropriate

setting in Menu No. 46; otherwise the filter will not function.

VR8

Bottom cover

CN9

CN8

Filter

CN16

Component side

VS-3

Advertising