2.5.2 Checking Out the System Without an IRD

Data Connection

To ensure that the system is configured and operating properly,
you will need to check the data provided in the system’s startup
routine.

To do so, you need to connect a PC to the antenna baseplate’s
maintenance port. The diagnostics procedure requires terminal
emulation software such as PROCOMM or Windows Terminal or
Hyperterminal. Use the settings appropriate to your application.

1. Connect one end of a PC data cable to the

maintenance port connector located on the rear of
the switchplate (see Figure 2-16). To access this
connector, you may need to remove the switchplate from
the mounting surface.

2. Connect the other end of the PC data cable to the

serial port on the PC (a 9-pin/25-pin connector
adapter may be needed for some PCs).

3. Open the terminal emulation software and

establish the following settings:

• 9600 baud

• no parity

• 8 data bits

• 1 start bit

• 1 stop bit

• no flow control

2-15

Installation

54-0195 Rev. A

Figure 2-17
PC Data Cable DB9 Connector

Maintenance Port
(DB9 Connector)

Figure 2-16
Switchplate Maintenance Port