5 - failed ird status check, 6 - ird faulty, 5 failed ird status check – KVH Industries TracVision L2 User Manual

Page 40: 6 ird faulty

Advertising
background image

4.2.5 Failed IRD Status Check

As detailed in

Appendix E

, TracVision L2 completes a detailed

startup routine whenever it is turned on. One of the first checks
is the IRD status test. As noted in the typical startup cycles, the
expectation is that the IRD and its communications link to
TracVision L2 will pass this test. There are, however, two
alternate results, each indicating a slightly different problem.

Test Result: NONE

If the system tests achieves a result of

NONE

, there is no

communication at all between the antenna unit and the IRD.

Solution

Check to be certain the IRD and TracVision L2 are connected
properly at the low-speed data port and that both are powered
on. Refer to

Section 2.3, “Connecting System Components”

for

correct antenna unit to IRD wiring procedures and diagrams.
After verifying the connection, cycle the power off and on and
review the startup test results.

Test Result: UNKNOWN

In the instance of a result of

UNKNOWN

, a communications link

exists, but the data received by the antenna unit is garbled and
unrecognizable.

Solution

As with a result of

NONE

, first check to be certain the IRD and

TracVision L2 are connected properly at the low-speed data port.
Refer to

Section 2.3, “Connecting System Components”

for correct

antenna unit to IRD wiring procedures and diagrams. After
verifying the connection, cycle the power off and on and review
the startup test results. If this does not initially succeed, refer to

Section 4.2.2, “AC Power Fluctuating,”

and follow the IRD reset

procedure.

4.2.6 IRD Faulty

In the case of a faulty IRD, refer to your IRD user manual for
service, replacement, and warranty information.