800P TruAlign Time Recorder User Guide

Page 32


With the display showing ‘CAL 2’, insert and

intentionally misalign the timecard, see

Figure 2.

With the timecard fully inserted and

misaligned, press and hold the

-

button to

register the alignment.

Note the value showing on the display. Shift

the card slightly left and right, the value will

increase or decrease.

When the display is at the highest value,

release the

-

button, the display will show

‘END’.

Remove the timecard. Subtract the smaller

registration value from the larger; the

difference should be greater than 50. If the

value is less than 50 you should repeat the

TruAlign calibration.

Press the SET button to complete the

calibration. The time recorder will go to the

normal time/date display with the changes

to the TruAlign calibration applied.

C A L 2

E n d

Figure 2

Misalignment of

timecard.