OPERATION

B-3

CONTROLS AND SETTINGS

All operator controls and welding connections are
located on the Case Front of the machine. See Figure
B.1 for the location of each control and connection.

FIGURE B.1- CV-300 Operator Controls and
Connections.

1. ON/OFF POWER SWITCH

- Two position

toggle switch that controls input power to the
machine.

2. WIRE FEEDER VOLTMETER SWITCH

-

This switch selects the polarity of the wire feeder
voltmeter, if so equipped. When welding electrode
positive (MIG, Outershield and some Innershield
processes) set the switch to "+".

When welding electrode negative (most Innershield
electrodes), set the switch to "-".

NOTE: This switch has no effect on the welding polar-
ity. In fact, if the wire feeder being used does not have
a voltmeter, the setting of this switch has no effect.

3. LOCAL/REMOTE SWITCH

- When switch is

in the LOCAL position, the welding voltage is con-
trolled at the CV-300. When the switch is the
REMOTE position, the welding voltage is con-
trolled remotely by a remote output control.

4. VOLTAGE ADJUSTMENT CONTROL

KNOB

- Controls the CV-300 output voltage.