Duty Cycle

Amps

Volts at Rated Amps

CV-300

100%

300A

32

60%

400A

36

Current Range

Maximum Open Circuit Voltage

Auxiliary Power

50A - 400A

55V

115 VAC, 5AMPS

42 VDC, 10AMPS

Input Voltage/

Fuse (Superlag)

Type 75

0

C wire in

Type 75

0

C Copper

Frequency

or Breaker Size

Copper conduit AWG

Ground Wire in Conduit

(IEC Sizes)

208/60

100

4 (25mm

2

)

6 (16mm

2

)

230/60

100

4 (25mm

2

)

8 (10mm

2

)

460/60

50

10 (6mm

2

)

10 (6mm

2

)

575/60

40

10 (6mm

2

)

10 (6mm

2

)

200/50/60

100

4 (25mm

2

)

6 (16mm

2

)

220/50/60

100

4 (25mm

2

)

8 (10mm

2

)

230/50/60

100

4 (25mm

2

)

8 (10mm

2

)

380/50/60

70

8 (10mm

2

)

8 (10mm

2

)

400/50/60

50

8 (10mm

2

)

10 (6mm

2

)

415/50/60

50

8 (10mm

2

)

10 (6mm

2

)

440/50/60

50

10 (6mm

2

)

10 (6mm

2

)

500/50/60

50

10 (6mm

2

)

10 (6mm

2

)

HEIGHT

WIDTH

DEPTH

LIFT HOOK

WEIGHT

ADD

21.5”

19.5”

27.0”

3.12”

300 lbs.

(546mm)

(495mm)

(686mm)

(80mm)

(136 Kg.)

Standard Voltages

Input Current at Rated Output

208/230/460/3/60

66/60/30 Amps

230/460/575/3/60

60/30/24 Amps

A-1

INSTALLATION

IDEALARC CV-300

A-1

TECHNICAL SPECIFICATIONS - IDEALARC CV-300

INPUT - THREE PHASE/ 50-60 HERTZ ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE & FUSE SIZE

PHYSICAL DIMENSIONS