CAPACITOR BANK REMOVAL AND REPLACEMENT (CONTINUED)
FIGURE F.17 - Capacitor Bank Removal.
OUTPUT CHOKE LEAD
LEAD #224
LEAD #224B
MOUNTING STRAP
POSITIVE
OUTPUT
LEAD
POSITIVE BUSS
D1 PIGTAIL
NEGATIVE BUSS
D2 PIGTAIL
D5 PIGTAIL
POSITIVE STRAP
D3 PIGTAIL
LEAD #224A
D4 PIGTAIL