Lincoln Impringer Conveyor Oven 1200 User Manual

Page 26

Advertising
background image

Impinger I -–1000 Series Service Manual - International

26

TROUBLESHOOTING GUIDE 1000 & 1200 / GAS OVENS


SYMPTOM POSSIBLE

CAUSE

EVALUATION

Incoming Power Supply

Check breakers/ Reset if required / Call Power Co.
if needed.

(Export Ovens)

For some export ovens, there is a control circuit
step-down transformer. This transformer steps
down supply voltage to 120 VAC. If main fan will
not run, the secondary of this transformer must be
checked for 120 VAC output. Check specific oven
model schematic for circuit location.

Oven Fan Fuse(s)

Check and/or Replace

Fuse Holder

Check and/or Replace

Fan Switch

Check continuity between switch terminals.

Main Relay

Check continuity to 120 VAC coil. Check for power
to relay coil (120 VAC). Check for 208/240 VAC to
relay terminals. Visually check for contact pull-in.

Fan Motor

Check for opens, shorts, or grounds. WITH
POWER OFF: Turn Fan Blade to check for locked
rotor.

Oven fan will not run

NOTE:

Capacitor

Check for opens, shorts, or grounds.

No Main Fan Cool
Down

Cool Down Thermostat

Check cool down thermostat (thermostat closes at
160°F and opens at 140°F). Check for power (120
VAC) at cool down thermostat. With the cool down
thermostat pre-heated, check for continuity. If
switch is open, replace.

No Control Box
Cooling(For ovens
equipped with Control
Box Cooling Fan)



NOTE:

Main Fan Relay



(Export Ovens)
Axial Cooling Fan

Check for power to Main Fan Relay. Visually check
for contact pull in.


(For ovens equipped with a control circuit step-
down transformer, the supply voltage for the
cooling fan is 240 VAC.)
WITH POWER OFF: check for locked rotor. Check
for power (120 VAC) to cooling fan. If 120 VAC is
present at the fan motor and the fan does not run,
replace fan assembly.

Incoming Power Supply

Check breakers/Reset if needed. Check for
incoming power (120 VAC)at cooling fan
thermostat.

Cooling Fan Thermostat

Check cooling fan thermostat (thermostat closes at
120°F and opens at 100°F). With cooling fan
thermostat pre-heated, check for continuity. If
switch is open, replace.

No automatic control
box cooling (For ovens
equipped with control
box cooling fan)

Axial Cooling Fan

Check for 120 VAC to cooling fan, if present and
fan does not run, replace fan.

Control box cooling fan
continues to run

Cooling Fan Thermostat

See "Cooling Fan Thermostat"

Check for 120 VAC to primary
of transformer. Check for 24
VAC from secondary of
transformer. If there is
primary voltage, but no
secondary voltage, replace
transformer.

Check for adequate gas supply to oven.

Manual Gas Shut-off Valve

Check to see that manual shut-off valve is open.

Fan Switch

Check to see that fan switch is "on".

Transformer, 24 VAC

Main Oven Fan

Check if main oven fan is operating. If not, refer to
"Oven fan will not run". Page 26.

Advertising