Tach generator and DC Motor 
Control Board 
With the power to the DC motor control board 
turned off, remove the leads from terminals T1 and 
T2. Place the test leads of a digital meter on the 
tach leads, turn power on, and the meter reading 
should be approximately 30 to 35 VDC. This 
reading should be steady within ± 0.2 to 0.3 VDC. If 
this reading is not within ± 0.5 VDC, place the test 
meter probes on terminals A+ and A-. The meter 
reading should be approximately 150 to 160 VDC 
and steady within approximately 2 VDC. If the tach. 
voltage is unsteady, and the board output is steady, 
check the coupling for loose set screws or any type 
of damage. If the coupling checks good, the tach. is 
usually bad. If the board voltage output is unsteady 
beyond limits, then the board is probably bad. 
Always check the speed pot. be sure it is okay 
before changing a board or tach. This test is not 
always 100% accurate as this test is not performed 
at operating speeds. However, this test is the best 
method currently available. Readjustment should 
always be attempted at least once before 
replacement. See procedure for board adjustment 
on page 65. 
DC Gear motor
If the DC control board is steady then the problem 
may be the motor or gearbox. Check the brushes in 
the motor for excessive arching and/or unusual 
wear. Check the motor and gearbox from 
instruction located on page 34 under "possible 
cause" listing "Conveyor gear motor". 
Conveyor will not run 
S/N Q14974 & up1000 
Series S/N Q14791 & 
up 1200 Series 
Voltage Supply
Check incoming voltage supply at Line 1 to neutral. 
There should be a voltage reading of 120 VAC. 
Fan Switch
See procedure for checking on page 26.
Conveyor Switch
Check for 120 VAC to conveyor Switch. If no 
voltage is present, trace wiring back to the fan 
switch. WITH POWER OFF: Check continuity 
between switch terminals. 
Conveyor Fuse (3A)
Check, replace if necessary.
Fuseholder
Check, replace if necessary.
Conveyor Control (Stepper) 
Transformer 
Check for 120 VAC supply to primary of 
transformer, if voltage is not present, trace wiring 
back to the fuse holder. If voltage is present, check 
for out-put voltage from the transformer secondary. 
NOTE: this control transformer outputs (2) 
secondary voltages Red Leads 29 VAC Brown 
Leads 10 VAC. If BOTH secondary voltages are 
not present, replace the transformer.