Impinger I -–1000 Series Service Manual - International
50
Main Flame will not 
stay lit 
Flame Monitor
(There should be a visible main flame at this time.) 
To check for flame monitor operation, connect a 
digital volt meter (capable of measuring D.C. micro 
amperes) between the flame sensor and terminal 
#15 on the flame monitor. The flame monitor 
requires a minimum of 4 micro amp. D.C. for proof 
of flame. If these readings are not achieved, 
replace sensor assembly. Also check for any type 
of damage to flame sensor wire and connections. 
If the reading is above the minimum required, and 
the flame monitor will not supply 220 VAC to the 
relay coil, replace the flame monitor. 
Intermittent Heating
As Follows
Both the main fan motor and burner blower motor 
are equipped with thermal protection and will cease 
to operate if overheating occurs. This can cause 
the units to cycle on and of intermittently. This may 
be caused by improper ventilation. Also, most of 
the problems listed under "oven will not heat" can 
cause intermittent failure. 
Conveyor Switch
Check for 120 VAC to conveyor switch. If no 
voltage is present, trace wiring back to the power 
supply. WITH POWER OFF: Check continuity 
between switch terminals 
Conveyor Fuse(3A)
Check, replace if necessary.
Fuseholder
Check, replace if necessary.
Conveyor Control
Check for 120 VAC supply to primary (Stepper) 
Transformer of transformer, if voltage is not 
present, trace wiring back to the fuseholder. If 
voltage is present, check for output voltage from 
the transformer secondary. NOTE: this control 
transformer outputs (2) secondary voltages: Red 
Leads 29 VAC Brown Leads 10 VAC. If BOTH 
secondary voltages are not present, replace the 
transformer. 
Conveyor will not run
Speed Adjustment 
Potentiometer 
This is a 0 to 50K ohm, 10 turn potentiometer. 
WITH POWER OFF: remove the 3 pin 
potentiometer cable plug from the motor control 
board. With a digital multimeter, check the ohm 
reading across the red lead to the black lead, this 
reading should be 50K ohms ± 5% as the 
potentiometer is rotated through its 10 turn rotation. 
Place the meter leads on the red lead and white 
lead. Rotating the potentiometer slowly, from low to 
high, the meter should show an even transition 
from 0 to 50K ohms ± 5% through the 10 turn 
rotation of the potentiometer. There should be no 
dead or open spots through the 10 turns of the 
potentiometer. Check all three leads to ground. 
There should be no continuity to ground. If any of 
the above checks fail, replace the potentiometer. 
Conveyor
Motor(Stepper)
Control
NOTE: if the conveyor drive motor becomes 
jammed or begins to run at an uncontrolled speed, 
the conveyor motor will stop running. To reset, turn 
off the conveyor switch, wait 30 seconds, turn the 
conveyor switch on. If the motor does not run after 
attempting re-set, check for 2 to 29 VAC across the 
motor terminals 1 to 2 and 3 to 5 on, the conveyor 
motor control. If voltage is not present at both sets 
of terminals, replace control.