GDK-20W DIGITAL WIRELESS KEY TELEPHONE SYSTEM

26



























Figure 3.4.3 RGU connector and protection switch setting

Following table shows the connector and switch on GDK-20W MBU.

Switch

ISSUE 1

Manufacturer

setting

Description Remark

Pin 1&2 short: 50Hz ring signal(sine wave)

CN23

RGU plugged: 25Hz ring signal(square wave)

Dependent on country
adaptation.

ON: For database protection.

1-1 ( OFF)

OFF: For system default.

Turn ON the switch
after system power on.

SW 1

1-2 (OFF)

OFF : Loop back OFF

OFF (Always)


The MBU has a two position DIP switch(SW1). The following is the function of each switch position :

Knob 1 System data base initialization when power on

-. On : Do not initialize system data base when power on.

-. Off : Initialize system data base when power on.

Knob 2 ISDN Loop Back on

-. On : Loop Back on

-. Off : Loop Back off

Before programming the system, SW1(knob 1) should be placed in the Off position and turn the system power off and on
to initialize the system database to default. Once the database has been initialized, SW(knob 1) should be placed in the
on position to protect the database in the memory. Refer to Figure 3.4.3.