2 system capacity – LG GDK-20W User Manual

Page 9

Advertising
background image

GDK-20W DIGITAL WIRELESS KEY TELEPHONE SYSTEM

11


2.2 SYSTEM CAPACITY

The following Table and Chart provide system capacities and display the system's configuration flexibility.

Table 2.2.1 System Capacities

Description

Basic & Expansion

Total

Time Slots

96

CO Line Ports

Max. 8 (analog CO and/or

ISDN BRI)

Max direct Station connections

6(+4 via 2B modules)

Max Stations via 2B modules

4

Max Stations via ISDN So bus

4

Max DECT terminals

20

DSS/DLS Consoles per station

0

Attendant Positions

1-System

Intercom Links

Non-blocking

Paging
-. All Call
-. Internal

1 zone

2 zones

Station Speed Dial

20/station, 24 digits each

20

System Speed Dial

24 digits each

79

Last Number Redial

32 digits

Music Source Inputs

2/PMU

2

External Control Contacts

1/MBU, 1/MFB

2

Alarm Input

1/MBU

1

RS-232C Ports

1/MFB

1

DTMF Receivers

2/PMU

2

CO Line Groups

4

Intercom Groups

4

Conference

3-party

no limit


* Note

1. Not all maximum capacities may be achieved simultaneously.

2. DECT terminals can be registered and used up to 20 stations. But GDK-20W system supports the only four(4)

simultaneous calls basically because the MBU has one wireless terminal interface circuit.
When WTIB card is installed to SLOT5, the number of simultaneous calls is increased up to the twelve(12)(One
base station provides the four(4) simultaneous calls.).

The WTIB has the two(2) wireless terminal interface ports.

3. One RS-232C port can be installed in the position of the MFB. The purpose of RS-232C port can be

programmable in Admin station programming.

It is recommended that the RS-232C serial cable whose length is below 10 meters is used.











Advertising