12. Alarm mode display / only displayed while operating.

CO : The sensor for sensing room temperature is open or short.

C1 : The sensor for sensing piping temperature is open or short.

13. Energy Saving

➀ If setting temperature of starting energy saving operation is under 22°C(71.6°F), first, setting temperature it

up to 22°C(71.6°F) and perform energy saving operation.

➁ After energy saving operation starts, if adaptation time of the human body pass from the point which room

temperature and setting temperature meet together, increase setting temperature 1°C(1.8°F) more.

➂ If it doesn't satisfy number ➀ even in 50 minutes from the start of energy saving operation, increase

1°C(1.8°F).

➃ After increasing setting temperature 1°C(1.8°F) more by number ➀, ➁, perform number ➁, ➂ again, if setting

temperature goes up to 25°C(77.0°F), maintain this temperature.

➄ If setting temperature goes down to under 25°C(77.0°F), during the operation, do number ➁, ➂, ➃ again.

14. AUTO RESTART

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.

15. Function of changing set temperature when re-operation after stop.

Operation is set the following condition when re-operation with start/stop button.

1.Operation mode.

Cooling/soft dry mode

Cooling mode

Heating mode

Heating mode

2. Setting the set temperature when cooling operation.

Room temperature > Set temperature: to be set to the previous set temperature.
Room temperature

≤ Set temperature

a) Room temperature

≥ 26°C(78.8°F): to be set to 24°C(75.2°F)

b) 22°C(71.6°F)

≤ Room temperature ≤ 25°C(77.0°F): to be set to 21°C(69.8°F)

c) 19°C(66.2°F)

≤ Room temperature ≤ 21°C(69.8°F): to be set to -1°C(1.8°F) less than room temperature.

d) Room temperature

≤ 18°C(64.4°F): to be set to 18°C(64.4°F)

–21–

Setting energy

saving operation

Setting temp.
23

°C(73.4°F)

21

°C(69.8°F)

22

°C(71.6°F)

23

°C(73.4°F)

24

°C(75.2°F)

25˚C(77.0

°F)

26

°C(78.8°F)

27

°C(80.6°F)

Setting temp.
24

°C(75.2°F)

Setting temp.
25

°C(77.0°F)

maintains setting temp.

25

°C(77.0°F)

28min.

50min.

50min.

50min.

35min.

47min.