3) Airflow Direction does not operate.

YES

NO

YES

NO

YES

NO

YES

NO

YES

NO

Is the unit operating?

Is the Auto Swing S/W "ON"?

Is the DC5V at 16 terminal?

(MICOM)

Is the DC12V

at each terminal?

(RY-Sync COIL)

Check the synchronous
motor winding.

Replacement RY-Sync
Check synchronous connector
contact point.

Is the AC220V(240V)

at each terminal

(SYN. MOTOR CONNECTOR)?

Replacement ICO2M

Replacement MICOM

The power ON/OFF S/W ON

Press the Auto Swing S/W