–31–

The unit is working, but not cooling and heating sufficiently

(Both blower and compressor are working)

WHAT TROUBLED

COMPLAINTS

HOW TO CHECK

REMEDY

Load

Air flow

Short air volume

Refrigerant

Air passage

Air filter

Much heat load

Obstacle disturbs Intake
of uniform wind.

Reverse rotation of
blower.

Shortage in the charged
refrigerant.

Improper or foreign bodies

Clogged with dust

Heat load increased.
Window or door has many
cracks or gaps.

Checking

Checking

Coil inlet pipe is frosted

Checking

Checking

Do necessary disposal
respectively.

Correct it.

Correct it.

Replenish it.
(Repair the leakage spot).

Correct or clear the
foreign bodies.

Cleaning

9.4 All the functions are performed normally, but very noisily and much vibratively.

WHAT TROUBLED

COMPLAINTS

HOW TO CHECK

REMEDY

Compressor

Blower

Screws

• Checking

• Checking

Checking

Checking

• Remove the shipping

bracket.

• Replace the

compressor

• Repair or replace it.
• Clear the other

material

Repair

Liquid refrigerant flooding
back from the evaporator.

Compressor shipping
bracket is not removed.

Faulty discharge valve and
suction valve.

Fan broken.

Other materials intruded.

Looseness or fail-off of
screws

• Check for refrigerant over-charge.
• Check to see if the intaking air temperature is

extremely cold.

• Check for insufficient air flow quantity.