8

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

p

ipe

C

learanCes

All installations using a vertical termination cap must

maintain one inch clearance between the direct vent pipe

and combustibles. For horizontal runs of pipe, one inch of

clearance to combustibles on the sides and bottom, and

two inches on the top of the pipe is required. See page 14

for allowable pipe configurations.

5-5/8”

(14mm)

10”

(54mm)

8-7/8”

(5mm)

Leg on Combustible

Carpet

1-1/” Maximum

C

learanCes

to

C

ombustibles

Minimum clearances to combustible materials in inches

(millimeters):

Parallel Installation

Corner Installation

a

lCove

dimensions

The minimum width between the alcove side walls is 51”

1295mm). The minimum height of the alcove is 46” (1168mm)

and the maximum depth is 35” (889mm).

f

loor

p

roteCtion

A non-combustible hearth pad is not required. This stove

may be installed on a combustible surface as long as the

combustible material (such as carpeting) does not extend

1-1/2” (38mm) vertically above the bottom of the base.

Also, the floor beneath the stove must be stable, level, hard,

and strong enough to support the stove without a tipping

hazard.

51”

(195mm)

Min.

5”

(889mm)

Max.

4”

(118mm)

Min.

Alcove Dimensions

Figure 4

Figure 5

Figure 