Step 3. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a

guideline and do not supersede local codes

in any way. Install vent according to local

codes, these instructions, the current National

Fuel Gas Code (ANSI-Z223.1) in the USA or

the current standards of CAN/CSA-B149.1 in

Canada.

Ensure clearances are in accordance with

local installation codes and the requirements

of the gas supplier.

Dégagement conforme aux codes d'installation

locaux et aux exigences du foumisseunde

gaz.

Use only approved venting components.

See Approved Vent Components on

Page 2.

These fireplaces must be vented directly

to the outside.

The vent system may not service multiple ap-

pliances, and must never be connected to a flue

serving a solid fuel burning appliance. The vent

pipe is tested to be run inside an enclosed

wall (such as a chase). There is no requirement

for inspection openings in the enclosing wall

at any of the joints in the vent pipe.

Select Venting System - Horizontal or Verti-

cal

With the appliance secured in framing, de-

termine vent routing and identify the exterior

termination location. The following sections

describe vertical (roof) and horizontal (exterior

wall) vent applications. Refer to the section

relating to your installation. A list of approved

venting components are shown in the tables

on Page 32.