Gas valve, Gas solid line connector gas flex line connector – Lennox Hearth ADAGIO-EN User Manual

Page 24

Advertising
background image

24

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

BLOWER CONTROL CIRCUIT WIRING

120V, 60HZ, 1PH

Factory Wired

Ground

Field Wired

Junction Box

Tab Intact

Tab

Broken

Plug blower

into this

receptacle

ne

er

G -

dn

uor

G

* Wall-mounted

ON/ OFF Blower

Switch or Variable

Speed Control Switch.

Blower

eti

h

W -

lar

tu

eN 12

0

VA

C

- B

la

ck

Green

Ground

Screw

W

hi

te

Gr

ee

n

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Red

Black

Figure 38 -

J-BOX WIRING

Step 6. CONNECTING GAS LINE

All codes require a shut-off valve mounted in

the supply line. The orientation of the shut-off

valve should face the front. Figure 39 illustrates

two methods for connecting the gas supply.

A Sediment Trap is recommended to prevent

moisture and debris in gas line from damaging

the valve.

The flex-line method is acceptable in the U.S.A.

where local codes permit, however, Canadian

requirements vary depending on locality. Instal-

lation must be in compliance with local codes.

These appliances are equipped with a gas flex-

line for use in connecting the unit to the gas line.

See Figure 39 for flex-line description. The

flex-line is rated for both natural and propane

gas. A manual shut off valve is also provided

with the flex-line.

Step 5.

WIRING - OPTIONAL FORCED AIR

BLOWER KIT

(millivolt models only)

(See Figure 36 on Page 23)

An electrical outlet box is provided for the

installation of the LBLK-100 forced air blower

kit. Electrical power must be provided to this

box to operate these blowers. Install the blower

kit according to the installation instructions

provided with the kit.

If the blower kit is to be installed at the time of

installation or at a later date, the main power sup-

ply and wall switch must be installed at the time of

installation. This will require that the electrical

connections must be made BEFORE the fireplace

is framed and enclosed in the finished walls.

Route a 3-wire, 120 VAC, 60 Hz, 1 ph power

supply and connect to electrical receptacle wires

and wall switch or wall rheostat.

Gas Valve

Burner

ON/OFF Switch

Push Button

Piezo Igniter

Figure 40 - Control Compartment

Glass Door

Gas Shut-

Off Valve

Gas Flex-

Line

Gas

Valve

3/8" NPT x

Flare Fitting

3/8" Flex Tubing

3/8" Nipple

3/8" Union

3/8" Close

Nipple

3/8" Shut-off Valve

1/2" x 3/8"

Reducer

Gas

Stub

1/2" x 3/8" Flare

Shut-off Valve

Gas Solid Line Connector

Gas Flex Line Connector

*Sediment

Trap

3"

Min

Figure 39 -

GAS CONNECTION

If required, access the valve (see Figure 40 ) by

opening the lower control panel (see instruction

sheet provided with the facade kit for additional

information about the control panel).

The millivolt and electronic control valve has a

3/8" (10 mm) NPT thread gas supply inlet.

Bring the shutoff valve on the end of the flex-line

over to the hard pipe and tighten with wrenches

from above through the firebox opening.

Secure all joints tightly using appropriate

tools and sealing compounds (ensure propane

resistant compounds are used in propane ap-

plications). It is recommended to seal around

the gas line to prevent cold air leakage.

Note: The gas supply line

must be installed in accor-

dance with building codes

by a qualified installer

approved and/or licensed

as required by the locality.

In the Commonwealth of

Massachusetts, installation

must be performed by a

licensed plumber or gas

fitter.