Warning, Avertissement – Lennox Hearth ADAGIO-EN User Manual

Page 2

Advertising
background image

2

TABLE OF CONTENTS

Packaging .........................................Page 2
Introduction ......................................Page 2
General Information ..........................Page 2
Requirements for Commonwealth
of Massachusetts ............................Page 4
New York City, New York (MEA) ......... Page 4
Cold Climate Insulation ....................... Page 5
Manufactured Home Requirements .... Page 5
Location Page ...................................... 5
Vent Termination Clearances .............. Page 6
Appliance and Vent Clearances ........... Page 8
Detailed Installation Steps .................Page 9
Typical Installation Sequence ...........Page 9
Step 1. Framing ...............................Page 9
Fireplace and Framing Specifications ..Page 10
Facade Specifications ........................Page 11
Step 2. Routing Gas Line ................Page 12
Step 3. Install the Vent System .......Page 13
Vertical Termination Systems ............Page 14
Vent Section Length Chart ................Page 14
Vertical Vent Tables and Figures ........Page 17
Horizontal Termination System .........Page 18
Horizontal Vent Tables and Figures ...Page 20
Venting Using Flexible Vent Pipe .......Page 22
Step 4. Field Wiring .........................Page 23
Step 5. Optional Blower Kit Wiring ..Page 24
Step 6. Connecting Gas Line ...........Page 24
Step 7. Verifying Appliance Operation Page 25
Step 8. Installing Logs ...................Page 26
Step 9. Install Glass Door ...............Page 28
Step 10. Burner Adjustments ............Page 29
Finishing Requirements ....................Page 30
Step 11. Attaching Safety-in-
Operation Warnings
.....................Page 31
Installation Accessories ....................Page 32
Gas Conversion Kits ..........................Page 33

Please read and understand these

instructions before beginning your

installation.

PACKAGING

The assembled vented gas fireplace heater is

packaged with:

1 - One log set located in firebox.

2 - One envelope containing the literature

package, which consists of the care and

operation manual, installation instruc-

tions, gas control labels and warranty;

envelope is located in the control compart-

ment.

3 - One bag of glowing embers, located in the

control compartment.

4 - One log support bracket, located in fire-

box.

Also requires (sold separately):
5 - One of the following firebox liner kits:

a. Firebox Liner Kit, Red Rustic Liner

b. Firebox Liner Kit, Red Herringbone Liner

c. Firebox Liner Kit, Cobblestone Liner

d. Firebox Liner Kit, Stucco Liner

6 - One of the following facade kits:

a. Arch Face-Black *

b. Arch Face-Nickel *

c. Garden Gate - Vintage Iron

d. Garden Gate - Vintage Copper

* If an arch face facade kit is purchased, a filigree

insert kit is also required (sold separately). The

filigree kits are available in 3 different styles and

4 attractive finishes.

INTRODUCTION

The Millivolt appliances have a millivolt gas

control valve with piezo ignition system. If any

optional accessories that will require electrical

power are to be installed, the electrical power

must be provided at the time of appliance

installation.

The Electronic appliances have an electronic

intermittent pilot ignition system. External

electrical pow-er is required to operate these

appliances.

These vented gas fireplace heaters are sealed

combustion, air-circulating gas fireplaces de-

signed for residential applications.

Use Only These Approved Vent Components

- These fireplaces are designed, tested and

listed for operation and installation with, the

following (4-1/2" inner and 7-1/2" outer) vent

components only:

Secure Vent™ Direct-vent System Compo-

nents manufactured by Security Chimneys

International,

Secure Flex™ Flexible Vent Components

manufactured by Security Chimneys Inter-

national and

Z-FLEX™ Model GA Venting Systems listed

to UL1777 and ULCS635 manufactured by

Flexmaster Canada Limited.

These approved vent system components are

labeled for identification. DO NOT use any

other manufacturer's vent components with

these appliances.

WARNING

Young children should be care-

fully supervised when they are

in the same room as the appli-

ance. Toddlers, young children

and others may be susceptible

to accidental contact burns. A

physical barrier is recommended

if there are at risk individuals in

the house. To restrict access to

a fireplace or stove, install an

adjustable safety gate to keep

toddlers, young children and

other at risk individuals out of

the room and away from hot

surfaces.

AVERTISSEMENT

Les jeunes enfants devraient être

surveillés étroitement lorsqu’ils

se trouvent dans la même pièce

que l’appareil. Les tout petits,

les jeunes enfants ou les adultes

peuvent subir des brûlures s’ils

viennent en contact avec la sur-

face chaude. Il est recommandé

d’installer une barrière physique

si des personnes à risques habi-

tent la maison. Pour empêcher

l’accès à un foyer ou à un poêle,

installez une barrière de sécu-

rité; cette mesure empêchera les

tout petits, les jeunes enfants et

toute autre personne à risque

d’avoir accès à la pièce et aux

surfaces chaudes.

GENERAL INFORMATION

Children and adults should be alerted to the

hazards of high surface temperature and

should stay away to avoid burns or clothing

ignition.

Les enfants et les adultes devraient être infor-

més des dangers que posent les températures

de surface élevées et se tenir à distance afin

d’éviter des brûlures ou que leurs vêtements

ne s’enflamment.

DO NOT ATTEMPT TO ALTER OR MODIFY

THE CONSTRUCTION OF THE APPLIANCE OR

ITS COMPONENTS. ANY MODIFICATION OR

ALTERATION MAY VOID THE WARRANTY, CER-

TIFICATION AND LISTINGS OF THIS UNIT.